DELTA CU Control Unit
![]() |
Unrivalled top performance!APV was first in the market when we introduced the famous "Red Top" control unit almost 20 years ago. Now we are first to introduce a new generation of control units designed to meet both the demands of modern automated processing, and the challenges of the wet and aggressive environments of the food, beverage and pharmaceutical industries. On the basis of our "Red Tops" long successful track record we have created a new control unit with improved performance and a number of new features that make it unique in the market. |
Features & benefits
Multi-voltage operation
Designed for multi-voltage operation, i.e. both for
solenoid valves and feed back switches. This means that one type of
control unit covers all the most common voltages.
Electronic fuse protected
The solenoid valve is protected in case of voltage spikes
and the Hall proximity switches are also protected against reverse
polarity.
No external plugs
All electrical wires run directly to the screw terminal which
reduces the risk of corrosion and water ingress considerably.
Clear signals
LED-indicators display valve position as well as power and solenoid
status.
Detachable control head with quick release
coupling
Air or electricity does not have to be disconnected during
maintenance. One single grip separates actuator and control head
completely and blocks off the air supply. This feature greatly
facilitates maintenance and replacement, and furthermore, all
electric components remain 100% sealed off from the ambient
environment.
One control head fits a variety of valve types
The control head is mounted on an adapter which is screwed
onto the actuator. This means that with different adapters, the
same control head may be used on many different valve types and
sizes.
Built-in throttle valve
Opening and closing speed for the valve actuator can be easily
regulated by means of two built-in throttle valves.
Silencer fitted as standard equipment
The standard mounted silencer considerably reduces the
unpleasant noise from the air exhaust and therefore enhances
working conditions. As an option, a hose may be fitted here to lead
away exhaust air.
Manual activation possible
The valve can be manually activated, if required, for
instance in connection with adjustment of the Hall-element.
Prepared for:
- 2 cable connections which facilitates use of external sensors
- Centred CIP-connection
- 3 solenoid valves
For further information, please see datasheets here.

